Product Specification :-

Measuring RangemmHg 700mmHg
Measuring Error ±1.5mmHg(3mmHg intraocularpressure 25mmHg)±2.5mmHg(25mmH intraocularpressure≤70mmHg)
Transport and Storage Ambient temperature 20°~+55°Relative moisture:95%: Atmosphere pressure:500hPa ** 1060hPa: Ambient temperature:+5~+40°: Relative moisture:80%: Atmosphere pressure:700hPa ~1060hPa
Running Relative moisture:95%: Atmosphere pressure:500hPa ** 1060hPa: Ambient temperature:+5~+40°: Relative moisture:80%: Atmosphere pressure:700hPa ~1060hPa: Rating voltage: DC3V(2 AA Betteires): Rating input power:1VA
Get Latest Price

Product Description

The Matronix Rebound Tonometer is a high-precision, user-friendly device designed to deliver rapid and reliable intraocular pressure (IOP) measurements—vital for glaucoma screening and comprehensive ocular diagnostics. Compact and battery-operated, this tonometer combines clinical-grade accuracy with field-ready convenience.

With a wide measuring range of up to 700 mmHg and high accuracy—±1.5 mmHg around 25 mmHg and ±2.5 mmHg for pressures up to 70 mmHg—it ensures dependable results across a broad range of patient conditions. Powered by two AA batteries, the device operates efficiently at just 1VA, making it ideal for portable use.

Built to perform under various clinical and environmental conditions, it functions optimally at temperatures between +5°C to +40°C and humidity up to 80%. Its robust construction also supports storage in harsher conditions, withstanding temperatures from -20°C to +55°C and relative humidity up to 95%.

Lightweight, durable, and easy to operate, the Matronix Rebound Tonometer is an essential addition to modern eye care setups, both in-clinic and on the go. Backed by Matronix's commitment to quality, it offers a trusted solution for fast and accurate IOP assessment.

Comparison Of Rebound Tonometer

Products Rebound Tonometer Applanation Tonometer Applanation Tonometer Zeiss
Features Rebound Tonometer Applanation Tonometer Applanation Tonometer Zeiss
Measurement Principle Rebound (no-contact probe rebound) Goldmann applanation Goldmann applanation (Zeiss-compatible)
Measurement Range Up to 70 mmHg 0–10.64 kPa 0–10.64 kPa
Patient Contact probe contact , no slit lamp required Requires corneal contact & slit lamp Requires corneal contact & slit lamp
Anesthesia Requirement Not required Required Required
Clinical Accuracy Focus Rapid screening & pediatric use Standard clinical IOP measurement Reference-standard IOP measurement
Ease of Use Very easy, handheld Operator-dependent Operator-dependent
Portability Fully portable Slit-lamp mounted Slit-lamp mounted
Power Source Battery powered (DC 3V, AA batteries) Mechanical (slit lamp based) Mechanical (slit lamp based)
Slit Lamp Compatibility Not required General slit lamp mounting Zeiss slit lamps (Series 66 & suspension arm)
Best for Pediatric / Non-cooperative Patients
Screening vs Diagnostic Screening & follow-ups Diagnostic standard Diagnostic gold standard
Clinical Setting Camps, bedside, outreach Clinics & hospitals Hospitals & advanced clinics